Wren Kitchens

Client Wren Kitchens
Location Paisley
Project Value < £10k
Completion Date June 2026
HF Divisions Involved
Project Overview

Following an emergency call-out after a local power cut, the HF HVACR team diagnosed terminal PCB failures on two legacy, 14-year-old air conditioning systems at Wren Kitchens in Paisley. Rather than patching obsolete infrastructure, we collaborated closely with our client, Penguin FM, to propose a forward-thinking, sustainable replacement strategy.

By replacing the aging units with modern, energy-efficient R32 systems, upgrading the supporting pipework, and future-proofing the branch against escalating R410A phase-out costs, we delivered an economical, high-performance climate solution that ensures long-term operational resilience for the retail venue.

Project Sectors

Full Project Details
Carrying out repairs of an air conditioning system at Wren Kitchens in Paisley
Air conditioning install at Wren Kitchens in Paisley

When a critical commercial site suffers a sudden power interruption, the immediate priority is asset stabilisation. Following a recent power cut at the prominent Wren Kitchens showroom in Paisley, our HVACR team was rapidly deployed on an emergency call-out to investigate localised climate control failures.

Upon arrival, our engineers conducted comprehensive diagnostics on two independent, legacy split air conditioning networks, identifying that four indoor fan coil units (FCUs) were entirely non-operational.

Engineering Diagnostics & The Core Challenge

Deep fault-finding procedures revealed that the severe electrical surge from the power cut had critically damaged the external Printed Circuit Boards (PCBs).

Because the existing equipment was 14 years old, the client was faced with an operational crossroads:

  • Procuring obsolete replacement parts for aging hardware running on R410A refrigerant (a gas rapidly escalating in cost due to strict, ongoing global phase-out quotas).
  • Executing a strategic upgrade to modern, high-density infrastructure designed for long-term commercial output.

Liaising transparently with our intermediary client, Penguin FM, we presented a detailed commercial roadmap outlining the economic risks of maintaining the legacy units versus the immediate sustainability returns of an upgrade. Backed by this data, the decision was made by Wren Kitchens to bypass short-term patches and completely replace the broken assets.

Technical Execution

Operating efficiently to minimise disruption to the live retail environment, our HVACR team executed a complete, clean strip-out and modern installation:

  • Hardware Replacement: Dismantled and safely disposed of the two failed outdoor compressors and the four corresponding indoor FCUs.
  • Infrastructure Upgrades: Upgraded the legacy structural pipework networks completely to match the pressure and thermal characteristics required by modern technology.
  • Rigorous Testing Protocol: Conducted high-pressure nitrogen strength testing, deep system evacuation to remove moisture, and precise additional refrigerant trims to confirm optimal operational pressures.
  • The Transition to R32: Commissioned the new systems utilising next-generation R32 refrigerant, maximising thermal capacity while drastically lowering the asset’s direct environmental footprint.

Operational ROI & Sustainability Impact Matrix

  • Future-Proof Asset Protection: By proactively migrating away from R410A, Wren Kitchens eliminates vulnerability to the skyrocketing maintenance and supply costs driven by the F-Gas phase-out regulations.
  • Energy Efficiency Gains: The new R32 architecture significantly lowers electricity consumption per kilowatt of cooling/heating output, instantly reducing the showroom’s ongoing operational overheads.
  • Extended System Lifespan: The brand-new system completely resets the asset lifecycle clock, guaranteeing reliable, prolonged climate comfort for both staff and visiting showroom customers.

By moving past standard “break-fix” maintenance and acting as genuine strategic partners, we helped Wren Kitchens transform an unexpected electrical failure into a major victory for their corporate sustainability goals.

By executing all diagnostics, pipework modification, and gas commissioning under one roof, our HVACR team has set a clear benchmark for responsive, commercially minded retail engineering.

Ready to start a project?

Contact our team today to discuss your requirements.

Enquire Now
HF Group Accreditation - ConstructionLine Gold Member
HF Group Accreditation - NSI Gold Fire & Security Member
HF Group Accreditation - BAFE Fire Safety Accredited
HF Group Accreditation - NICEIC Approved Electricians
HF Group Accreditation - Refcom Gas Certification
HF Group Accreditation - Select Approved Electricians
HF Group Accreditation - CHAS Approved Contractors
HF Group Accreditation - SNIPEF Plumbing & Heating Approved Contractor
HF Group Accreditation - OFTEC Approved Mechanical Contractor
HF Group Accreditation - SafeContractor
HF Group Accreditation - Gas Safe Approved Heating Engineers
HF Group Accreditation - Acclaim Accredited
HF Group Accreditation - Emergency Lighting Installer
HF Group Accreditation - Cyber Essentials Accredited
HF Group Accreditation - IFC Smoke Vent Installer Certified
HF Group Accreditation - ISO 414001 2015 Accredited
HF Group Accreditation - ISO 9001 2015 Accredited
HF Group Accreditation - 45001 2018 Accredited
HF Group Accreditation - Daikin Business Partner
HF Group Accreditation - SEPA Certified
HF Group Accreditation - Mitsubishi Accredited Installer
HF Group Accreditation - WaterSafe Approved Contractor
HF Group Accreditation - ConstructionLine Gold Member
HF Group Accreditation - NSI Gold Fire & Security Member
HF Group Accreditation - BAFE Fire Safety Accredited
HF Group Accreditation - NICEIC Approved Electricians
HF Group Accreditation - Refcom Gas Certification
HF Group Accreditation - Select Approved Electricians
HF Group Accreditation - CHAS Approved Contractors
HF Group Accreditation - SNIPEF Plumbing & Heating Approved Contractor
HF Group Accreditation - OFTEC Approved Mechanical Contractor
HF Group Accreditation - SafeContractor
HF Group Accreditation - Gas Safe Approved Heating Engineers
HF Group Accreditation - Acclaim Accredited
HF Group Accreditation - Emergency Lighting Installer
HF Group Accreditation - Cyber Essentials Accredited
HF Group Accreditation - IFC Smoke Vent Installer Certified
HF Group Accreditation - ISO 414001 2015 Accredited
HF Group Accreditation - ISO 9001 2015 Accredited
HF Group Accreditation - 45001 2018 Accredited
HF Group Accreditation - Daikin Business Partner
HF Group Accreditation - SEPA Certified
HF Group Accreditation - Mitsubishi Accredited Installer
HF Group Accreditation - WaterSafe Approved Contractor

Our Latest News

From technical insights to our latest project updates, stay connected with everything going on at HF.

Head office

100 Albert Drive
Glasgow, G41 2SJ

Contact us

0800 783 9480